Analisis Unjuk Kerja Prototype Trainer Lemari Pendingin dengan Variasi Beban Pendinginan

Andi Arifudin, I Gede Wiratmaja, I Nyoman Pasek Nugraha

Abstract


This study aimed to find the effect of variations in cooling load on the performance of the prototype trainer refrigerator, which in this refrigerator prototype had never been tested performance. In this study, the experimental method was used. The values sought in this study were the rate of room cooling and the Coefficient of Performance (COP). In this study, the variation of the cooling load used started from temperatures of 300, 350, 400, 450 oC, with 15 repetitions, and the temperature performance used was 1000C. The study results showed that the highest room cooling rate occurred at 300 oC cooling load variation, namely 0.00265, and the smallest room cooling rate occurred at 450 oC cooling load variation, namely 0.00174. The highest Coefficient of Performance (COP) results occurred at a cooling load variation of 450 oC, namely 34.09, and the lowest Coefficient of Performance (COP) occurred at a cooling load variation of 300 oC, namely 29.60. From these results, it can be concluded that the cooling rate of the room was inversely proportional to the increase in cooling load because the more significant the cooling load, the longer the time obtained, resulting in a small room cooling rate. And for the results of the Coefficient of Performance (COP), it was directly proportional to the increase in the cooling load because the more significant the cooling load given, the higher the temperature at T1 and T2, resulting in a significant Coefficient of Performance (COP).


Keywords


Prototype Trainer Refrigerator; Room Cooling Rate; Coefficient of Performance.

Full Text:

PDF

References


Mastur, M., Setiyawan, K., & Sugiantoro, B. 2017. Pengaruh Variasi Beban, Waktu Pendinginan dan Temperatur Ruang terhadap Performasi Mesin Pendingin. Techno (Jurnal Fakultas Teknik, Universitas Muhammadiyah Purwokerto), 17(1), 043-047.

Purnomo, B. C., Widodo, N., Munahar, S., & Nugroho, D. 2020. KarakteristikRefrigeran Musicool Dalam Mesin Refrigerasi Kompresi Uap Menggunakan Evaporator Ganda. Quantum Teknika: Jurnal Teknik Mesin Terapan, 1(2), 48-54.

Purwanto, E., & Ridhuan, K. 2014. Pengaruh Jenis Refrigerant dan Beban Pendinginan Terhadap Kemampuan Kerja Mesin Pendingin. 2014. Turbo : Jurnal Program Studi Teknik Mesin, 3(1), 11–16. DOI: http://dx.doi.org/10.24127/trb.v3i1. 19

Putra, R. P. 2020. Analisis Pengaruh Variasi Beban Pendinginan Ruangan terhadap Unjuk Kerja Prototype Mini Water Chiller (Undergraduate thesis, Universitas Pendidikan Ganesha).

Setyawan, T. 2020. Pengembangan Alat Peraga Lemari Pendingin sebagai Media Pembelajaran pada Mata Kuliah Perancangan Sistem Refrigerasi (Undergraduate thesis, Universitas Pendidikan Ganesha).

Supriana, P. D., Dantes, K. R., & Nugraha, I. N. P. 2019. Pengaruh Variasi Fluida Pendingin terhadap Capaian Suhu Optimal pada Rancangan Mesin Pendingin Mini Water Chiller. Jurnal Pendidikan Teknik Mesin Undiksha, 7(1), 36-42.




DOI: https://doi.org/10.18196/jqt.v3i1.12225

Refbacks

  • There are currently no refbacks.


Copyright (c) 2021 Quantum Teknika : Jurnal Teknik Mesin Terapan

License URL: https://creativecommons.org/licenses/by-nc/4.0/

Quantum Teknika : Jurnal Teknik Mesin Terapan is indexed by :

 

Office:

Editorial of Quantum Teknika, Building D, Jl. Brawijaya, Tamantirto, Kasihan, Bantul, Yogyakarta.

Telp: (0274) 387656
Fax: (0274) 387646
WA: +62896-7470-8638 (Mirza Yusuf)
Email: jqt@umy.ac.id

Creative Commons License
Quantum Teknika : Jurnal Teknik Mesin Terapan is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.