Pemeriksaan Kecepatan Enap Darah (Ked) pada Posisi Tegak Dibanding Kemiringan 30°

Linda Rosita

Abstract


Erytrocyt sedimentation rate (ESR) is one blood test which always to do help diagnosis. There is for to find out different value ESR position straight is compared ESR position 30°. Helply this position will give faster time all at least last than one hour. The amount total of vena blood 62 taking from 62 respondent, at RSUD Wirosaban and clinical pathology laboratory Indonesia of Islamic Univercity . The method of collect to do with result ESR position straight one hour, also position 30°. The collected data is process with analysis paired sample test. The result is different between the position of staight one hour and the position 30° in 5 menit, 15 menit, and 30 menit, (p-0,00). To need the next research on the position 30° with time varition, than try the hook position not more than 30°.

Kecepatan Enap darah (KED merupakan salah satu pemeriksaan yang selalu dilakukan untuk membantu menegakan diagnosis. Adapun tujuan penelitian adalah membandingkan nilai KED pada posisi tegak dengan posisi kemiringan 30°, dengan harapan posisi kemiringan dapat memberikan waktu yang lebih singkat atau kurang dari 1 jam untuk mendapatkan nilai yang sama pada posisi tegak. Jumlah sampel darah vena 62, diambil dari 62 responden, dari pasien RSUD Wirosaban dan Laboratorium Patologi Klinik FK UII. Metode pengumpulan mencatat nilai pengamatan KED pada posisi tegak waktu 1 jam, posisi miring 30 derajat pada waktu 5’, 15’ dan 30’ kemudian diolah dengan analisis statistik uji selisih 2 rata-rata. Terdapat perbedaan antara nilai pengamatan posisi tegak 1 jam dengan posisi miring arah 5’, 15’ dan 30’ (p = 0,00). Diperlukan penelitian lebih lanjut pada posisi miring 30’ dengan waktu yang bervariasi, serta mencoba posisi kemiringan tegak hanya 30°.


Keywords


Kecepatan endap darah; posisi tegak; kemiringan 30°; Erytrocyt sedimentation rate (ESR); position straight; position 30°

Full Text:

PDF

References


Rodak.. Hematology: Clinical Principles And Applications. Philadelphia: W. B. Saunders Company, 1995; 166-168

Widmann, Tinjauan Klinis Atas Nilai Pemeriksaan Laboratorium, EGC, Jakarta, 1989; 33-34

Koepkc john AMD, Lotspiech Cheryl AMS MBA MT (ASCD) CLN Steine Anne E, PhD MT. Clinical Haematology, 9 lh.ed. New York: Lippincott, Philadelphia, 1998; 117-120.

Dacie SJV, Lewis SM. Miscellaneous Test. In : Dacie SJV. Pratical Haematology, 8 *. ed. Singapore Publ. Ptc, 1995; 521-525

Henry JB. Clinical Diagnosis and Managemant by Laboratory Method, 18

Davidsohn I, Nelson DA. The Blood. In : Davidsohn I, Henry JB. Tood Sanford : Clinical Diagnosis by Laboratory Method, 14th. ed. Philadelphia: WB Sanders Co, 1969; 152-154.

Saadeh C. The Erytrocyte Sedimentation Rate: Old and New Clinical Applications. South Med. Journal 1998; 3 ; 220-225.

Gardner, Gregory, et al. Erytrocyte Sedimentation Rate, University of Washington School of Medicine, 1996.

Brigden Malcom, Clinical Utility of the Erytrocyte Sedimentation Rate, American Familiy Physi¬cian, 1999.




DOI: https://doi.org/10.18196/mmjkk.v4i1.1711

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.


      

Editorial Office:
Journal Room, G1 (Biomedic) Building, Ground Floor, Faculty of Medicine and Health Science Universitas Muhammadiyah Yogyakarta, 
Jalan Lingkar Selatan (Brawijaya), Tamantirto, Kasihan, Bantul, Daerah Istimewa Yogyakarta, Indonesia
Phone: +62 274 387 656 (ext: 231)
WA : +62 811-2650-303
Website: http://journal.umy.ac.id/index.php/mm 
E-mail: mmjkk@umy.university

Creative Commons License
Mutiara Medika: Jurnal Kedokteran dan Kesehatan is licensed under a Creative Commons Attribution 4.0 International License. View My Stats