Pengaruh Variasi Insulator Saluran Chilled Water Terhadap Performansi Prototype Mini Water Chiller

Buddhi Satya Utama, I Nyoman Pasek Nugraha, I Gede Wiratmaja

Abstract


The high heat transfer rate from the environment to the chilled water pipe will affect the performance of the mini water chiller prototype, so it is necessary to insulate the chilled water pipe using the right insulator to optimize the performance of the mini water chiller prototype. Therefore, this study aims to determine the effect of the chilled water pipe insulator variations: nitrile rubber expanded and polyurethane foam on the optimal temperature and cooling rate of the mini water chiller prototype cabin. The method used in this study is an experimental method with a variation of the insulator as independent variables and the optimal temperature also cooling rate of the mini water chiller prototype cabin as the dependent variables. The testing process was carried out 20 times repetition of data collection on each variation using a stopwatch, thermo gun, thermostat, ampere pliers, a bulb, and a water heating element as a tool in research. In addition, it expanded nitrile rubber and polyurethane foam spray as research material. The results obtained from this study showed that the average optimal temperature achievement of the mini water chiller prototype with polyurethane foam insulator was 11.242◦C, and with the nitrile rubber expanded insulator was 11.250◦C. Otherwise, the average cooling rate of the mini water chiller prototype cabin with polyurethane foam insulator variation was 0.001421◦C, while in the variation of nitrile rubber expanded it was 0.001032◦C, which indicates that there is an effect of chilled water pipe insulator variations on the performance of the mini water chiller prototype.


Keywords


Insulation; Performance; Prototype Mini Water Chiller

Full Text:

PDF

References


Deshmukh, G., Birwal, P., Datir, R., & Patel, S. 2017. Thermal insulation materials: A tool for energy conservation. Journal of Food Processing & Technology, 8(04), 1-5.

Kayana, M. D., Nugraha, I. N. P., & Dantes, K. R. 2019. Analisa Pengaruh Laju Aliran Fluida Air pada Saluran Pipa AHU (Air Handling Unit) terhadap Capaian Suhu Optimum Mesin Pendingin Mini Water Chiler. Jurnal Pendidikan Teknik Mesin Undiksha, 7(3), 129-134.

Muntolib, & Rusdiyantoro. 2014. Analisa Bahan Isolasi Pipa Saluran Uap Panas Pada Boiler untuk Meminimalisasi Heat Loss. Jurnal Teknik WAKTU, 12(02), 50–56.

Purnomo, B. C., Widodo, N., Munahar, S., & Nugroho, D. 2020. Karakteristik Refrigeran Musicool Dalam Mesin Refrigerasi Kompresi Uap Menggunakan Evaporator Ganda. Quantum Teknika: Jurnal Teknik Mesin Terapan, 1(2), 48-54.

Supriana, P. D., Dantes, K. R., & Nugraha, I. N. P. 2019. Pengaruh Variasi Fluida Pendingin terhadap Capaian Suhu Optimal pada Rancangan Mesin Pendingin Mini Water Chiller. Jurnal Pendidikan Teknik Mesin Undiksha, 7(1), 36-42.




DOI: https://doi.org/10.18196/jqt.v3i1.12264

Refbacks

  • There are currently no refbacks.


Copyright (c) 2021 Quantum Teknika : Jurnal Teknik Mesin Terapan



Quantum Teknika : Jurnal Teknik Mesin Terapan is indexed by :

 

Office:

Editorial of Quantum Teknika, Building D, Jl. Brawijaya, Tamantirto, Kasihan, Bantul, Yogyakarta.

Telp: (0274) 387656
Fax: (0274) 387646
WA: +62896-7470-8638 (Mirza Yusuf)
Email: jqt@umy.ac.id

Creative Commons License
Quantum Teknika : Jurnal Teknik Mesin Terapan is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.