Evaluation and Strengthening Recommendations of Rectorate Building Muhammadiyah University of Sumatra Barat Due to Earthquake

Asiya Nurhasanah Habirun, Deddy Kurniawan, Muhammad Fajri Ad'ha

Abstract


The UM Sumbar Rectorate building suffered structural damage after 33 years. During service life, earthquakes have frequently occurred, the largest was 7.6 magnitude earthquake 2009 in Padang. The structural components have never been handled. This study aims to identify the existing condition as a basis for handling structural damage. Research activities are structure inspection, structural analysis, and determining structural improvements. The building has been deflected by >1° (± 10cm). The majority of structural elements are cracked due to overcapacity. Based on ATC 40 pushover analysis results, it found that 10 steps on x-direction and 11 steps on y-direction of push loads on the structure until it collapsed. Structure performance level is Life Safety, which is in a plastic condition. Strengthening are suggested to increasing column, building ductility, and implementing a dilation system. Evaluation the foundation structure and soil investigation are necessary before planning the strengthening.

Keywords


Structure Assessment; Earthquake; Pushover; Retrofit

Full Text:

PDF

References


Amri, S. (2006). Teknologi audit forensik, repair dan retrofit untuk rumah dan bangunan gedung Ed. 1 (1st ed.). Yayasan John Hi-Tech Idetama.

Apriani, W., Yos, J., Km, S., & Pekanbaru, R. (2016). Aplikasi non destructive test pada investigasi keandalan struktur beton. Siklus : Jurnal Teknik Sipil, 2(2), 95 – 103–195 – 103. https://doi.org/10.31849/SIKLUS.V2I2.345

ATC-40. (1996). Seismic evaluation and retrofit of concrete buildings. Redwood City, CA: Applied Technology Council. In Seismic safety commisionsion (Vol. 1, Issue November 1996, p. 334).

Batara, I. (2021). Contoh desain struktur bangunan dengan SAP2000.

Fauzan, F., Ismail, F. A., Putri, L. M., & Viviayana, D. (2010). Analisa kerusakan struktur bangunan gedung ″A″ SMAN 10 Padang akibat gempa 30 September 2009. Jurnal Rekayasa Sipil (JRS-Unand), 6(2), 31. https://doi.org/10.25077/jrs.6.2.31-40.2010

Gotami, R., & Aswin, M. (2020). Pengaruh tulangan baja yang terkorosi HCL terhadap kapasitas dan perilaku lentur balok beton bertulang. Repositori Institusi Universitas Sumatera Utara (RI-USU).

Habirun, A. N. (2021a). Perkuatan elemen struktur balok gedung perkantoran dengan usia layan 40 tahun menggunakan CFRP. 7th ACE Conference, 244–250.

Habirun, A. N. (2021b). Studi ketahanan elemen struktur balok dan pelat gedung perkantoran dengan usia layan 40 Tahun. Ensiklopedia of Journal, 3(3), 275–281. https://doi.org/10.33559/EOJ.V3I3.817

Habirun, A. N. (2023). Studi ketahanan elemen struktur kolom gedung perkantoran dengan usia layan 40 tahun. Rang Teknik Journal, 6(1), 196–200. https://doi.org/10.31869/RTJ.V6I1.3930

Hakiki, R. (2023). Investigasi kerusakan pada struktur gedung Plasa Telkom Padang Sidempuan. JURNAL GRADASI TEKNIK SIPIL, 7(1), 100–108. https://doi.org/10.31961/gradasi.v7i1.1637

Hutagalung, P. L., Onty, B., & Sihombing, E. (2021). Penggunaan non destructive test pada investigasi keandalan struktur beton jembatan (Studi kasus: Jembatan Aek Sibarosak Kab. Mandailing Natal). ATDS SAINTECH JOURNAL OF ENGINEERING, 2(2), 17–21. https://ojs.atds.ac.id/index.php/atdssaintech/article/view/25

Ismail, F. A., Hakam, A., & Fauzan, F. (2011). Kerusakan Bangunan Hotel Bumi Minang Akibat Gempa Padang 30 September 2009. Jurnal Teknik Sipil, 18(2), 1–8. https://doi.org/10.5614/JTS.2011.18.2.5

Kurniawan, D., Habirun, A. N., & Pratama, A. (2024). Evaluasi struktur gedung Fakultas Hukum Universitas Muhammadiyah Sumatera Barat. Rang Teknik Journal, 7(1), 184–192. https://doi.org/10.31869/RTJ.V7I1.4985

Kurniawan, K., Sungkono, D., Arbianto, R., Yuono, T., Handoyo, S., Mulyandari, E., Wijayanti, P., Dinasty Purnomoasri, R. A., & Hartanto, T. (2024). Evaluasi bangunan gedung perkuliahan Fakultas Pertanian Universitas Tunas Pembangunan Surakarta. GANESHA: Jurnal Pengabdian Masyarakat, 4(1), 49–54. https://doi.org/10.36728/GANESHA.V4I1.3066

Monikha Sari, M., Kusumaningrum, E., & Teguh, M. (2013). Evaluasi kerusakan gedung Exim Plaza Yogyakarta akibat gempa dan metode perbaikannya. Prosiding Seminar Nasional Aplikasi Teknologi Prasarana Wilayah (ATPW, 1–13.

Sumargo, S., Ruslan, U., & Ghulam, M. (2014). Kapasitas penggunaan carbon fiber reinforced polymer (CFRP) berlapis banyak terhadap perkuatan lentur struktur balok beton bertulang. Prosiding Industrial Research Workshop and National Seminar, 5, 126–133. https://doi.org/10.35313/IRWNS.V5I0.417

Sumpena, H., Bastian, E., & Habirun, A. N. (2023). Evaluasi kinerja struktur gedung denah L SDN 04 Garegeh Kota Bukittinggi dengan metode analisis non linier. Ensiklopedia Research and Community Service Review, 3(1), 68–76. https://jurnal.ensiklopediaku.org/ojs-2.4.8-3/index.php/erw/article/view/2131

Yanto, N., Imani, R., & Andika, Z. (2019). Evaluasi kinerja struktur gedung Rumah Sakit Paru Sumatera Barat dengan pushover analysis. Civil Engineering Collaboration, 1–9. https://doi.org/10.35134/JCIVIL.V4I2.1




DOI: https://doi.org/10.18196/st.v27i1.20088

Refbacks

  • There are currently no refbacks.


Copyright (c) 2024 Asiya Nurhasanah Habirun, Deddy Kurniawan, Muhammad Fajri Ad’ha

Editorial Office :

SEMESTA TEKNIKA

Faculty of Engineering, Universitas Muhammadiyah Yogyakarta.

Jln. Brawijaya Tamantirto Kasihan Bantul 55183 Indonesia

Telp:(62)274-387656, Fax.:(62)274-387656

Email: semesta_teknika@umy.ac.id, semestateknika@umy.university

Website: http://http://journal.umy.ac.id/index.php/st

Creative Commons License

Semesta Teknika is licensed under a Creative Commons Attribution 4.0 International License.