Efek Variasi Beban Pendinginan Terhadap Coefficient Of Performance (Cop) Alat Uji Pengukuran Koefisien Evaporasi Menggunakan Refrigeran R-134A

Tito Hadji Agung Santosa, Muhammad Nadjib, Thoharuddin Thoharuddin, Muhammad Akhid Riza

Abstract


Investigation of the cooling load effect toward Coefficient of Performance (COP) is important to conduct. The Coefficient of Performance (COP) is related with compressor work and refrigeration capacity in order to produce a refrigeration system which have a high COP. The high COP value can be reached with minimum compressor work, however it has a maximum refrigeration capacity. This research is to know the effect of cooling load variation toward the performance of experimental device of evaporation heat transfer measurement. By knowing the changing of performance toward cooling load variation, it can be useful in design of an effective and efficient air conditioning system.The method of coolecting data is by experimental method that is by varying water mass flowrate (cooling load) which is flowed to evaporator. An evaporator is soak in a 30 xm x 15 cm x 20 cm water box. Water flowrate can be varied and be masured by a water rotameter. Refrigerant is using Freon R-134a. Experiment is conducted with an evaporation heat transfer coefficient device. The device is a model of modified refrigeration system by adding instruments : an orifice, a test section, and an electric heater. Thermocouple and some pressure gauges is installed at some points which has been determined. Thermocouple and pressure gauges is used to collect temperature and pressure data. After conducting an experiment by evaporator cooling load variation, temperature and pressure data is got. Furthermore based on the temperature and pressure data, the enthalpy is got and can be used to counting the compressor power. Refrigeration capacity can be counted from total heat absorbed by evaporator from water and is divided refrigerant mass flowrate. In this research is got results that cooling load given in evaporator enfluences the COP of the experiment device. By increasing in cooling load at the determined variation, the Coefficient of Performance (COP) of the device is increase. In this research it get results increasing of COP at some refrigerant mass flowrate. The maximum result is get at minimum range inverter variation, that is 16 Hz (ṁr = 9,4 g/s - 10,26 g/s) and the maximum cooling load variation is 2 LPM with COP of 4,96. Whereas the minimum results is get at the maximum inverter range variation, that is 24 Hz (ṁr = 11,83 g/s - 12,25 g/s) and the minimum cooling load variation is 1 LPM with COP of 1,98. This research give some information, if a cooling load of an air conditioning room is chanhing, then it will change the parameter (temperature and pressure) and COP of the air conditioning system in a room.


Keywords


Evaporation Coefficient Device, R-134a, Cooling load, Coefficient of Performance (COP)

Full Text:

PDF

References


Anwar, Khairil. 2010. “Efek Beban Pendingin Terhadap Performa Sistem Mesin Pendingin”. Palu: Universitas Tadulako.

Cengel Y.A., Boles M.A. 1989. “Thermodynamics: An Engineering Approach”. Mc Graw-Hill

Dewitt D.P., Incropera, F.P. 2002. “Fundamental of Heat and Mass Transfer”. Jefferson City: John Wiley & Sons Inc.

Hariyanto, Agus. 2015. “Perpindahan Panas”. Yogyakarta: Innosain.

Kuncara, Purba. 2013. “Cara Menghitung Kapasitas AC Berdasarkan Besar Ruangan. http://purbakuncara.com/cara-menghitung-kapasitas-ac-berdasar-besar-ruangan/ diakses pada 18 Juni 2017 pukul 16.01 WIB

Kharagpur. 2008. “Refrigeration and Air Conditioning”. Version I ME. India

Kurniawan, Bayu Abdi. 2007. “Analisis Termal Unjuk Kerja Heat Exchanger 11-E-7 Di Kilang Fuel Oil Complex IPT Pertamina UP IV Cilacap”. Yogyakarta: Universitas Muhammadiyah Yogyakarta.

Moch. Rizal A.Y., Ilminnafik, Listyadi. 2013. “Pengaruh Variasi Beban Pendingin Terhadap Prestasi Kerja Mesin Pendingin Dengan Refrigeran R12 dan LPG”. Jember: Universitas Jember.

Nadjib, Muhammad. 2005. “Buku Ajar Teknik Refrigerasi dan Kriogenik” Yogyakarta: Universitas Muhammadiyah Yogyakarta.

Pitts, Donald., Sissom, Leighton. 2011. “Schaums’s Outline: Perpindahan Kalor, Edisi Kedua”. Jakarta: Penerbit Erlangga.

Santosa, Tito Hadji. 2003. “Pengukuran Koefisien Perpindahan Kalor Evaporasi Refrigeran Petrozon Rossy 12 di Dalam Saluran Halus Horisontal”. Yogyakarta: Universitas Gadjah Mada.

Stoecker, W.F., Jerold W. Jones, Supratman Hara. 1996. “Refrigerasi dan Pengkondisian Udara Edisi Kedua”. Jakarta: Penerbit Erlangga.

Subarkah, Agus. 2011. “Sejarah Sistem Pengkondisian Udara/Air Conditioning”. http://agus-subarkah.blogspot.co.id/2011/10/sejarah-sistem-pengkondisian-udara.html diakses pada 17 Juni 2017 pukul 04.43 WIB

Wicaksono, Bartholomeus D.A. 2014. “Pemanfaatan Panas Buang Mesin Pendingin Untuk Pengering Pakaian”. Yogyakarta: Universitas Sanata Dharma.

Yasmin. 2011. “Beban Pendinginan dan Penghematannya”. Pelatihan Dasar audit Energi dan Komisioning Gedung B2TE-BPPT.

Yunianto, Bambang. 2005. “Pengaruh Perubahan Temperatur Evaporator Terhadap Prestasi Air Cooled Chiller Dengan Refrigeran R-134a, Pada Temperatur Kodensor Tetap”. Semarang: Universitas Diponegoro.

Wastam. 2010. “Pengaruh Variasi Kerja Fan, Boiler, dan Pre-Heater pada Mesin Air Conditioning Laboratory Unit A660 Terhadap Coefficient of Performance”. Yogyakarta: Universitas Muhammadiyah Yogyakarta.

https://www.ohio.edu/mechanical/thermo/Intro/Chapt.1_6/Chapter4c.html diakses pada 17 Juni 2017 pukul 04.49 WIB




DOI: https://doi.org/10.18196/st.v20i2.3412

Refbacks

  • There are currently no refbacks.


Copyright (c) 2017 Jurnal Semesta Teknika

Editorial Office :

SEMESTA TEKNIKA

Faculty of Engineering, Universitas Muhammadiyah Yogyakarta.

Jln. Brawijaya Tamantirto Kasihan Bantul 55183 Indonesia

Telp:(62)274-387656, Fax.:(62)274-387656

Email: semesta_teknika@umy.ac.id, semestateknika@umy.university

Website: http://http://journal.umy.ac.id/index.php/st

Creative Commons License

Semesta Teknika is licensed under a Creative Commons Attribution 4.0 International License.