Single Lead EMG signal to Control an Upper Limb Exoskeleton Using Embedded Machine Learning on Raspberry Pi

Triwiyanto Triwiyanto, Wahyu Caesarendra, Vugar Abdullayev, Abdussalam Ali Ahmed, Herianto Herianto

Abstract


Post-stroke can cause partial or complete paralysis of the human limb. Delayed rehabilitation steps in post-stroke patients can cause muscle atrophy and limb stiffness. Post-stroke patients require an upper limb exoskeleton device for the rehabilitation process. Several previous studies used more than one electrode lead to control the exoskeleton. The use of many electrode leads can lead to an increase in complexity in terms of hardware and software. Therefore, this research aims to develop single lead EMG pattern recognition to control an upper limb exoskeleton. The main contribution of this research is that the robotic upper limb exoskeleton device can be controlled using a single lead EMG. EMG signals were tapped at the biceps point with a sampling frequency of 2000 Hz. A Raspberry Pi 3B+ was used to embed the data acquisition, feature extraction, classification and motor control by using multithread algorithm. The exoskeleton arm frame is made using 3D printing technology using a high torque servo motor drive. The control process is carried out by extracting EMG signals using EMG features (mean absolute value, root mean square, variance) further extraction results will be trained on machine learning (decision tree (DT), linear regression (LR), polynomial regression (PR), and random forest (RF)). The results show that machine learning decision tree and random forest produce the highest accuracy compared to other classifiers. The accuracy of DT and RF are of 96.36±0.54% and 95.67±0.76%, respectively. Combining the EMG features, shows that there is no significant difference in accuracy (p-value >0.05). A single lead EMG electrode can control the upper limb exoskeleton robot device well.


Keywords


Upper limb exoskeleton; EMG signal; Raspberry Pi; machine learning; multi-thread

Full Text:

PDF

References


A. T. Bruno Peixoto, Susana Silva, Sofia Carreira, Dulce Sousa, Vivian Rezende, “Quality of life predictors after first stroke: A study with post-acute patients,” Neurology, Psychiatry and Brain Research, vol. 23, pp. 10–15, 2017.

D. Dutta, S. Sen, S. Aruchamy, and S. Mandal, “Prevalence of post-stroke upper extremity paresis in developing countries and significance of m-Health for rehabilitation after stroke - A review,” Smart Heal., vol. 23, p. 100264, 2022.

R. Small, P. H. Wilson, D. Wong, and J. M. Rogers, “Who, what, when, where, why, and how: A systematic review of the quality of post-stroke cognitive rehabilitation protocols,” Ann. Phys. Rehabil. Med., vol. 65, no. 5, p. 101623, 2022.

I. Boukhennoufa, X. Zhai, V. Utti, J. Jackson, and K. D. McDonald-Maier, “Wearable sensors and machine learning in post-stroke rehabilitation assessment: A systematic review,” Biomed. Signal Process. Control, vol. 71, p. 103197, 2022.

I. A. Marques et al., “Virtual reality and serious game therapy for post-stroke individuals: A preliminary study with humanized rehabilitation approach protocol,” Complement. Ther. Clin. Pract., vol. 49, p. 101681, 2022.

B. Yang, Y. Huang, Z. Li, and X. Hu, “Management of post-stroke depression (PSD) by electroencephalography for effective rehabilitation,” Eng. Regen., vol. 4, no. 1, pp. 44–54, 2023.

S. R. Badruni, A. M. Irwan, and S. Malasari, “Comparison of activity daily living performance among post-stroke older people with and without rehabilitation program,” Enferm. Clin., vol. 31, pp. S765–S768, 2021.

Z. Xiao, Z. Wang, S. Ge, Y. Zhong, and W. Zhang, “Rehabilitation efficacy comparison of virtual reality technology and computer-assisted cognitive rehabilitation in patients with post-stroke cognitive impairment: A network meta-analysis,” J. Clin. Neurosci., vol. 103, no. July, pp. 85–91, 2022.

S. Peznola, L. V. Gauthier, M. C. Claypool, B. Roop, and A. C. Lammert, “Compliance with in-home self-managed rehabilitation post-stroke is largely independent of scheduling approach,” Arch. Phys. Med. Rehabil., 2022.

Y. Na and J. Kim, “Dynamic Elbow Flexion Force Estimation Through a Muscle Twitch Model and sEMG in a Fatigue Condition,” IEEE Trans. Neural Syst. Rehabil. Eng., vol. 25, no. 1431-1439, pp. 1–1, 2017.

M. H. Rahman, M. J. Rahman, O. L. Cristobal, M. Saad, J. P. Kenné, and P. S. Archambault, “Development of a whole arm wearable robotic exoskeleton for rehabilitation and to assist upper limb movements,” Robotica, vol. 33, no. 1, pp. 19–39, 2015.

J. Lobo-Prat, P. N. Kooren, A. H. Stienen, J. L. Herder, B. F. Koopman, and P. H. Veltink, “Non-invasive control interfaces for intention detection in active movement-assistive devices.,” J. Neuroeng. Rehabil., vol. 11, no. 1, p. 168, 2014.

R. Yamada et al., “Factors related to daily step counts of stroke patients during hospitalization in a convalescent rehabilitation ward,” J. Stroke Cerebrovasc. Dis., vol. 31, no. 5, p. 106398, 2022.

Z.-Q. Yang, M.-F. Wei, L. Chen, and J.-N. Xi, “Research progress in the application of motor-cognitive dual- task training in rehabilitation of walking function in stroke patients,” J. Neurorestoratology, vol. 11, no. 1, p. 100028, 2022.

D. Park, K. J. Son, and H. S. Kim, “Chronic Phase Survival Rate in Stroke Patients With Severe Functional Limitations According to the Frequency of Rehabilitation Treatment,” Arch. Phys. Med. Rehabil., 2022.

C. L. Chu et al., “Recovery of walking ability in stroke patients through postacute care rehabilitation,” Biomed. J., 2022.

S. M. Taslim Reza, N. Ahmad, I. A. Choudhury, and R. A. Raja Ghazilla, “A fuzzy controller for lower limb exoskeletons during sit-to-stand and stand-to-sit movement using wearable sensors,” Sensors (Switzerland), vol. 14, no. 3, pp. 4342–4363, 2014.

H. Lee, P. W. Ferguson, and J. Rosen, Lower limb exoskeleton systems-overview. INC, 2019.

L. Lu, Q. Wu, X. Chen, Z. Shao, B. Chen, and H. Wu, “Development of a sEMG-based torque estimation control strategy for a soft elbow exoskeleton,” Rob. Auton. Syst., vol. 111, pp. 88–98, 2019.

I. Kagirov et al., “Medical exoskeleton ‘Remotion’ with an intelligent control system: Modeling, implementation, and testing,” Simul. Model. Pract. Theory, vol. 107, p. 102200, 2021.

A. Foroutannia, M. R. Akbarzadeh-T, and A. Akbarzadeh, “A deep learning strategy for EMG-based joint position prediction in hip exoskeleton assistive robots,” Biomed. Signal Process. Control, vol. 75, p. 103557, 2022.

O. A. Chittar and S. B. Barve, “Waist-Supportive Exoskeleton : Systems and Materials,” Mater. Today Proc., vol. 57, pp. 840–845, 2022.

Y. Sun, Y. Tang, J. Zheng, D. Dong, X. Chen, and L. Bai, “From sensing to control of lower limb exoskeleton: a systematic review,” Annu. Rev. Control, vol. 53, pp. 83–96, 2022.

Z. Zhang, Z. Wang, H. Lei, and W. Gu, “Gait phase recognition of lower limb exoskeleton system based on the integrated network model,” Biomed. Signal Process. Control, vol. 76, p. 103693, 2022.

T.-H. Hsu, C.-L. Tsai, J.-Y. Chi, C.-Y. Hsu, and Y.-N. Lin, “Effect of wearable exoskeleton on post-stroke gait: a systematic review and meta-analysis.,” Ann. Phys. Rehabil. Med., vol. 66, p. 101674, 2022.

Z. Tang, H. Yu, H. Yang, L. Zhang, and L. Zhang, “Effect of velocity and acceleration in joint angle estimation for an EMG-Based upper-limb exoskeleton control,” Comput. Biol. Med., vol. 141, p. 105156, 2022.

Z. Tang, K. Zhang, S. Sun, Z. Gao, L. Zhang, and Z. Yang, “An Upper-Limb Power-Assist Exoskeleton Using Proportional Myoelectric Control,” Sensors, vol. 14, no. 4, pp. 6677–6694, 2014.

A. Asokan and M. Vigneshwar, “Design and Control of an EMG-based Low-cost Exoskeleton for Stroke Rehabilitation,” 2019 Fifth Indian Control Conference (ICC), 2019, pp. 478-483.

R. Fuentes-Alvarez et al., “Assistive robotic exoskeleton using recurrent neural networks for decision taking for the robust trajectory tracking,” Expert Syst. Appl., vol. 193, p. 116482, 2022.

F. V. dos Anjos, M. Ghislieri, G. L. Cerone, T. P. Pinto, and M. Gazzoni, “Changes in the distribution of muscle activity when using a passive trunk exoskeleton depend on the type of working task: A high-density surface EMG study,” J. Biomech., vol. 130, p. 110846, 2022.

B. A. De la Cruz-Sánchez, M. Arias-Montiel, and E. Lugo-González, “EMG-controlled hand exoskeleton for assisted bilateral rehabilitation,” Biocybern. Biomed. Eng., vol. 42, no. 2, pp. 596–614, 2022.

E. Tetteh, M. S. Hallbeck, and G. A. Mirka, “Effects of passive exoskeleton support on EMG measures of the neck, shoulder and trunk muscles while holding simulated surgical postures and performing a simulated surgical procedure,” Appl. Ergon., vol. 100, p. 103646, 2022.

M. M. Alemi, J. Geissinger, A. A. Simon, S. E. Chang, and A. T. Asbeck, “A passive exoskeleton reduces peak and mean EMG during symmetric and asymmetric lifting,” J. Electromyogr. Kinesiol., vol. 47, pp. 25–34, 2019.

J. Park, S. J. Kim, S. Kyeong, J. Kim, and Y. Na, “Feasibility of proportional EMG control for a hand exoskeleton: A Fitts’ Law approach,” IFAC-PapersOnLine, vol. 51, no. 22, pp. 214–219, 2018.

P. Caliandro et al., “Exoskeleton-assisted gait in chronic stroke: An EMG and functional near-infrared spectroscopy study of muscle activation patterns and prefrontal cortex activity,” Clin. Neurophysiol., vol. 131, no. 8, pp. 1775–1781, 2020.

M. J. Jorgensen, N. A. Hakansson, and J. Desai, “Influence of different passive shoulder exoskeletons on shoulder and torso muscle activation during simulated horizontal and vertical aircraft squeeze riveting tasks,” Appl. Ergon., vol. 104, p. 103822, 2022.

M. J. Jorgensen, N. A. Hakansson, and J. Desai, “The impact of passive shoulder exoskeletons during simulated aircraft manufacturing sealing tasks,” Int. J. Ind. Ergon., vol. 91, p. 103337, 2022.

T. Triwiyanto et al., “Design of hand exoskeleton for paralysis with voice pattern recognition control,” J. Biomimetics, Biomater. Biomed. Eng., vol. 50, pp. 51–58, 2021.

S. Maddox, Paralysis resource guide, 4th ed. Washington: Paralysis Resource Center, 2017.

E. A. Courtney-long, “Prevalence and Causes of Paralysis,” Am. J. Public Health, vol. 106, no. 10, pp. 1855–1857, 2017.

I. Jo, J. Lee, Y. Park, and J. Bae, “Design of a wearable hand exoskeleton for exercising flexion/extension of the fingers,” in IEEE International Conference on Rehabilitation Robotics, 2017, pp. 1615–1620.

Z. Song and S. Zhang, “Preliminary Study on Continuous Recognition of Elbow Flexion / Extension Using sEMG Signals for Bilateral Rehabilitation,” Sensors, vol. 16, no. 10, p. 1739, 2016.

T. Triwiyanto, O. Wahyunggoro, H. A. Nugroho, and H. Herianto, “Muscle fatigue compensation of the electromyography signal for elbow joint angle estimation using adaptive feature,” Comput. Electr. Eng., vol. 71, pp. 284–293, 2018.

L. Bi, A. Feleke, and C. Guan, “A review on EMG-based motor intention prediction of continuous human upper limb motion for human-robot collaboration,” Biomed. Signal Process. Control, vol. 51, pp. 113–127, 2019.

Q. Wu and Y. Chen, “Adaptive cooperative control of a soft elbow rehabilitation exoskeleton based on improved joint torque estimation,” Mech. Syst. Signal Process., vol. 184, p. 109748, 2023.

A. Akhtar, N. Aghasadeghi, L. Hargrove, and T. Bretl, “Estimation of distal arm joint angles from EMG and shoulder orientation for transhumeral prostheses,” J. Electromyogr. Kinesiol., vol. 35, pp. 86–94, 2017.

G. Hajian, B. Behinaein, A. Etemad, and E. Morin, “Bagged tree ensemble modelling with feature selection for isometric EMG-based force estimation,” Biomed. Signal Process. Control, vol. 78, no. November 2021, p. 104012, 2022.

J. Li, R. Wang, and L. Pan, “An enhanced EMG-driven Musculoskeletal model based on non-negative matrix factorization,” Biomed. Signal Process. Control, vol. 79, 2023.

S. M. Rahman, M. A. Ali, and M. A. Al Mamun, “The Use of Wearable Sensors for the Classification of Electromyographic Signal Patterns based on Changes in the Elbow Joint Angle,” Procedia Comput. Sci., vol. 185, pp. 338–344, 2021.

F. Davarinia and A. Maleki, “SSVEP-gated EMG-based decoding of elbow angle during goal-directed reaching movement,” Biomed. Signal Process. Control, vol. 71, p. 103222, 2022.

M. Pang, S. Guo, Q. Huang, H. Ishihara, and H. Hirata, “Electromyography-based quantitative representation method for upper-limb elbow joint angle in sagittal plane,” Journal of Medical and Biological Engineering, vol. 35, no. 2. pp. 165–177, 2015.

Z. Li, B. Wang, F. Sun, C. Yang, Q. Xie, and W. Zhang, “SEMG-based joint force control for an upper-limb power-assist exoskeleton robot,” IEEE J. Biomed. Heal. Informatics, vol. 18, no. 3, pp. 1043–1050, 2014.

T. Triwiyanto, O. Wahyunggoro, and H. A. Nugroho, “Robust Features for Elbow Joint Angle Estimation Based on Electromyography,” Int. J. Adv. Sci. Eng. Inf. Technol., vol. 8, no. 5, pp. 1956–1961, 2018.

J. L. a S. Ramos and M. a Meggiolaro, “Use of surface electromyography for human amplification using an exoskeleton driven by artificial pneumatic muscles,” in 5th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics, 2014, pp. 585–590.

S. Göktepe, A. Menzel, and E. Kuhl, “The generalized Hill model: A kinematic approach towards active muscle contraction,” J. Mech. Phys. Solids, vol. 72, no. 1, pp. 20–39, 2014.

U. J. Naeem, C. Xiong, and A. a. Abdullah, “EMG-muscle force estimation model based on back-propagation neural network,” 2012 IEEE Int. Conf. Virtual Environ. Human-Computer Interfaces Meas. Syst. Proc., pp. 222–227, 2012.

H. Feys et al., “An EMG-controlled robotic hand exoskeleton for bilateral rehabilitation,” IEEE Trans. Haptics, vol. 8, no. 2, pp. 924–929, 2018.

Y. Li, W. Zhang, Q. Zhang, and N. Zheng, “Transfer Learning-Based Muscle Activity Decoding Scheme by Low-frequency sEMG for Wearable Low-cost Application,” IEEE Access, vol. 9, pp. 22804–22815, 2021.

T. Triwiyanto et al., “Hand Exoskeleton Development Based on Voice Recognition Using Embedded Machine Learning on Raspberry Pi,” J. Biomimetics, Biomater. Biomed. Eng., vol. 55, pp. 81–92, 2022.

J. B. Ullauri, L. Peternel, B. Ugurlu, Y. Yamada, and J. Morimoto, “On the EMG-based torque estimation for humans coupled with a force-controlled elbow exoskeleton,” in 2015 International Conference on Advanced Robotics (ICAR), 2015, pp. 302–307.

M. Pang, S. Guo, and Z. Song, “Study on the sEMG Driven Upper Limb Exoskeleton Rehabilitation Device in Bilateral Rehabilitation,” Journal of Robotics and Mechatronics, vol. 24, no. 4. pp. 585–594, 2012.

T. Triwiyanto, I. P. A. Pawana, B. G. Irianto, T. B. Indrato, and I. D. G. H. Wisana, “Embedded system for upper-limb exoskeleton based on electromyography control,” Telkomnika (Telecommunication Comput. Electron. Control., vol. 17, no. 6, pp. 2992–3002, 2019.

A. Sandberg, “Motor unit properties do not correlate between MUNIX and needle EMG in remote polio in the biceps brachii muscle,” Clin. Neurophysiol. Pract., vol. 8, pp. 24–31, 2023.

K. Kobayashi et al., “Application of statistical parametric mapping for comparison of scapular kinematics and EMG,” J. Biomech., vol. 145, p. 111357, 2022.

M. Silsby, A. F. Fois, C. Yiannikas, M. C. Kiernan, V. S. C. Fung, and S. Vucic, “12. EMG bursting characteristics of upper limb muscles in patients with CIDP and tremor,” Clin. Neurophysiol., vol. 131, no. 3, pp. e5–e6, 2020.

A. Del Vecchio, A. Holobar, D. Falla, F. Felici, R. M. Enoka, and D. Farina, “Tutorial: Analysis of motor unit discharge characteristics from high-density surface EMG signals,” J. Electromyogr. Kinesiol., vol. 53, p. 102426, 2020.

Y. Li, Z. Su, K. Chen, W. Zhang, and M. Du, “Application of an EMG interference filtering method to dynamic ECGs based on an adaptive wavelet-Wiener filter and adaptive moving average filter,” Biomed. Signal Process. Control, vol. 72, no. PB, p. 103344, 2022.

C. Tepe and M. C. Demir, “Real-Time Classification of EMG Myo Armband Data Using Support Vector Machine,” Irbm, vol. 43, no. 4, pp. 300–308, 2022.

A. López-Delis, A. F. Ruiz-Olaya, T. Freire-Bastos, and D. Delisle-Rodríguez, “A Comparison of Myoelectric Pattern Recognition Methods to Control an Upper Limb Active Exoskeleton,” Progress in Pattern Recognition, Image Analysis, Computer Vision, and Applications. CIARP 2013, Lecture Notes in Computer Science, vol 8259, 2013, pp. 100–107.

R. Couceiro, P. Carvalho, R. P. Paiva, J. Henriques, and J. Muehlsteff, “Detection of motion artifact patterns in photoplethysmographic signals based on time and period domain analysis,” Physiol. Meas., vol. 35, no. 12, pp. 2369–2388, 2014.

P. Geethanjali and K. K. Ray, “A Low-Cost Real-Time Research Platform for EMG Pattern Recognition-Based Prosthetic Hand,” IEEE/ASME Trans. Mechatronics, vol. 20, no. 4, pp. 1948–1955, Aug. 2015.

V. Kumar, “A new proposal for time domain features of EMG signal on individual basis over conventional space,” 4th IEEE Int. Conf. Signal Process. Comput. Control. ISPCC 2017, vol. 2017–Janua, pp. 531–535, 2017.

Triwiyanto, O. Wahyunggoro, H. A. Nugroho, and H. Herianto, “Quantitative Relationship Between Feature Extraction of sEMG and Upper Limb Elbow Joint Angle,” in 2016 International Seminar on Application for Technology of Information and Communication, 2016, pp. 44–50.

S. Ben-David and S. Shalev-Shwartz, Understanding Machine Learning: From Theory to Algorithms. 2014.

R. Alazrai, M. Abuhijleh, H. Alwanni, and M. I. Daoud, “A Deep Learning Framework for Decoding Motor Imagery Tasks of the Same Hand Using EEG Signals,” IEEE Access, vol. 7, pp. 109612–109627, 2019.

S. Basu, S. Mitra, and N. Saha, “Deep Learning for Screening COVID-19 using Chest X-Ray Images,” 2020 IEEE Symp. Ser. Comput. Intell. SSCI 2020, pp. 2521–2527, 2020.

J. A. García-gonz, L. A. Escudero-g, and M. Martínez-navarro, “What is happening in shrinking medium-sized cities ? A correlational analysis and a multiple linear regression model on the case of Spain,” Cities, vol. 134, p. 104205, 2023.

N. K. Mahanti, K. Upendar, and S. K. Chakraborty, “Comparison of artificial neural network and linear regression model for the leaf morphology of fenugreek (Trigonella foenum graecum) grown under different nitrogen fertilizer doses,” Smart Agric. Technol., vol. 2, p. 100058, 2022.

Z. Patonai, R. Kicsiny, and G. Géczi, “Multiple linear regression based model for the indoor temperature of mobile containers,” Heliyon, vol. 8, no. 12, 2022.

E. Carrizosa, L. H. Mortensen, D. Romero Morales, and M. R. Sillero-Denamiel, “The tree based linear regression model for hierarchical categorical variables,” Expert Syst. Appl., vol. 203, p. 117423, 2022.

Rasyidah, R. Efendi, N. M. Nawi, M. M. Deris, and S. M. A. Burney, “Cleansing of inconsistent sample in linear regression model based on rough sets theory,” Syst. Soft Comput., vol. 5, p. 200046, 2023.

A. Dwivedi, Y. Kwon, A. J. McDaid, and M. Liarokapis, “A Learning Scheme for EMG Based Decoding of Dexterous, In-Hand Manipulation Motions,” IEEE Trans. Neural Syst. Rehabil. Eng., vol. 27, no. 10, pp. 2205–2215, 2019.

Triwiyanto, O. Wahyunggoro, H. A. Nugroho, and H. Herianto, “DWT analysis of sEMG for muscle fatigue assessment of dynamic motion flexion-extension of elbow joint,” in Proceedings of 2016 8th International Conference on Information Technology and Electrical Engineering: Empowering Technology for Better Future, ICITEE 2016, 2017.

M. Gandolla et al., “Artificial neural network EMG classifier for functional hand grasp movements prediction,” J. Int. Med. Res., 2016.




DOI: https://doi.org/10.18196/jrc.v4i1.17364

Refbacks

  • There are currently no refbacks.


Copyright (c) 2023 Triwiyanto Triwiyanto, Wahyu Caesarendra, Vugar Abdullayev, Abdussalam Ali Ahmed, Herianto Herianto

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

 


Journal of Robotics and Control (JRC)

P-ISSN: 2715-5056 || E-ISSN: 2715-5072
Organized by Peneliti Teknologi Teknik Indonesia
Published by Universitas Muhammadiyah Yogyakarta in collaboration with Peneliti Teknologi Teknik Indonesia, Indonesia and the Department of Electrical Engineering
Website: http://journal.umy.ac.id/index.php/jrc
Email: jrcofumy@gmail.com


Kuliah Teknik Elektro Terbaik